BASE INFORMATION IES 200S, IES 400S, IES 600S & IES 1100S

IES Model No. IES 200S IES 400S IES 600S IES 1100S
Kawasaki Turbine Model No. S2A-02 SIT-02 S2A-01 M1A-01
Genset ISO Output kWe 200 394 664 1,118
Compressor - No. of Stages and Type 2 Certrifugal 2 Certrifugal 2 Certrifugal 2 Certrifugal
Turbine - No. of Stages and Type 2 Axial 2 Axial 3 Axial 3 Axial
Starting Battery Voltage 24 VDC 24 VDC 48 VDC 60 VDC

Starter Type:

Standard - DC Electric
Optional - Pneumatic (Air)

Fuel:

Standard - N0. 2 Diesel Fuel Oil
Optional - Natural Gas or Kerosene

TECHNICAL INFORMATION IES 200S, IES 400S, IES 600S & IES 1100S

IES model No. IES 200S IES 400S IES 600S IES 1100S
Fuel Pressure to Fuel Valve
1.  Liquid kPag (psig)
34 (5) 34 (5) 34 (5) 34 (5)
2. Gas kPag (psig)

1,310 (190)

1,310 (190) 1,310 
(190)
1,310 
(190)

SET WEIGHTS AND DIMENSIONS

IES model No. IES 200S IES 400S IES 600S IES 1100S
A. Open Skid Type, Engine/Gearbox and Generator
1) Length m (ft)
2.590 (8.5) 2.655 (8.7) 3.355 (11.0) 4.056 (13.3)
2. Width m (ft)

0.915 (3.0)

1.100 (3.6) 1.010 (3.3) 1.190 (3.9)
3. Height m (ft) 1.160 (3.8) 1.250 (4.1) 1.375 (4.5) 1.495 (4.9)
B. Fully Enclosed Type 
1) Length m (ft)
3.510 (11.5) 3.875 (12.7) 3.995 (13.1) 5.000 (16.4)
2) Width m (ft) 1.800 (5.9) 2.105 (6.9) 2.200 (7.2) 2.320 (7.6)
3) Height m (ft) 2.200 (7.2) 2.200 (7.2) 2.288 (7.5) 2.400 (7.9)
Set Weights (Approximate)
A. Engine Only kg (lb) 1,646 (3,630) 2,694 (5,940) 3,502 (7,720) 6,187 (13,640)
B. Open Skid Type Engine/Gearbox and Generator kg (lb) 1,646 (3,630) 2,694 (5,940) 3,502 (7,720) 6,187 (13,640)
C. Fully Enclosed Type Generator Set kg (lb) 5,987 (13,200) 7,983 (17,600) 9,980 (22,000) 13,970 (30,800)

NOTES:

1. Turbine generator performance ratings are nominal based on ISO conditions (unless noted): 15°C (59°F), 101.325 kPa (abs), (29.92 inHg (abs); or 14.696 psia), sea level, 60% relative humidity, no inlet or exhaust duct losses, LHV or fuel and no water or steam injection.

2. Liquid fuel lower heating value LHV 42.7984 MJ/kg (18,400 Btu/lb).

3. Gas fuel lower heating value LHV 33.9316 MJ/cubic metre (910.6966 Btu/scf).

4. 1 Btu = 1055.056 Joules (IST).

Above specifications are subject to change without notice.